Cannot install Oil And Gas 7.6.1.0 (or HSE 7.6.1.0) on the top of TPAE 7.6.0.8

May 8, 2017 AliceDegawa

Problem:
Error in the updatedb command while trying to install Maximo for Oil and Gas 7.6.1.0 (or Health, Safety and Environment Manager Release 7.6.1.0) on the top of TPAE 7.6.0.8.

 

Symptom:
During the updatedb process, when class V7610_127 is being updated, a unique key violation error occurs and the installation fails.

 

Resolving the problem:
Apply the Interim Fix for APAR IV95458 before running the updatedb command:
. For Oil and Gas, apply OG7610_ifixes.20170428-1454 (7.6.1.0-TIV-MAMOG-IF006) or later.
. For HSE, apply HSE7610_ifixes.20170428-1548 (7.6.1.0-TIV-MAMHSE-IF006) or later.

 

Steps:
1. Install TPAE 7.6.0.8.
2. Install OIL7610 (or HSE7610) but do not run the updatedb command.
3. Extract the files of the Interim Fix package into the <install_home> folder, selecting the Overwrite existing files and the Use folder names options.
4. Run the 'updatedb.bat' utility to run all the Interim Fix database scripts:
4.1. From a command prompt, change directory to '<install_home>\tools\maximo'. For example, c:\IBM\SMP\maximo\tools\maximo.
4.2. Run 'updatedb.bat'.
5. Run 'configdb.bat'.